Special box moulds

The precast concrete culvert elements, made in these two hydraulically operated moulds, are cast on their side, and turned 90° after demoulding by means of a turning device.
Because the elements were going to be placed at the base of a bored tunnel, the dimensions of the moulds had to cope with very strict technical specifications. The tolerance on the joint dimensions (machined shear key soffits and top recess formers with tongue and groove feature) was +/- 0,75mm.
The width, height, diagonal and radius had to be within a tolerance of +/- 1,5mm.
Special hydraulic and electronic features of the moulds, for making the moulds fool-proof and limiting labour as much as possible: